Gloss meter? What to choose and what to look for.

połyskomierz na powierzchni o dużym połysku

 

 

- Gloss meter

- Standards for gloss meters

- Units used to measure gloss

- Available models

- Measurement field

- Which angle to choose: 20°, 60°, or 85°?

- Gloss meter price

- Calibration standard and measurement differences

- Calibration data correction

 

 

Gloss meter  

 

Once we know that we have a problem with determining the gloss of our product, we start looking for a solution that will allow us to determine its values. Most often, during the first conversation with our customers, the question arises about a device for measuring gloss or simply a device that measures gloss. Other names also appear, such as gloss meter.

 

Standards for gloss meters 

3Color® devices have been developed based on international standards relating to the design and operation of this type of equipment, including ASTM D 523, D2457, DIN 67530, ISO 2813, ISO 7668, JIS Z8741, BS3900, and BS6161. Users of gloss meters should carefully read the specifications for their product in terms of device selection and measurement methods.

 

Available models

 

3Color® gloss meters are available in three product versions:

3Color® GM30

3Color® GM38

3Color® GM30s

 

 

The 3Color® GM30 model is a basic gloss meter that measures gloss only at an angle of 60° - it is a so-called single-angle gloss meter. The second model, GM38, is a multi-angle gloss meter, i.e. it operates across the entire gloss range at measurement angles of 20°, 60° and 85°. The GM30s model, like the GM30, is a single-angle gloss meter measuring gloss at an angle of 60°, but it uses a so-called micro-aperture with a measuring field of 2 mm x 3 mm.

 

Measurement field

 

Since we are talking about the measurement field, it is worth taking a closer look at this specification in order to adjust the size of our aperture to the tested detail or surface. The aforementioned GM30s model has a so-called micro aperture (Fig. 1), but other models require a much larger surface area to perform the measurement (Fig. 2). The user should check whether their material is large enough to cover the minimum field of the device. Please note that curved elements will require a smaller measurement field to compensate for the curvature of the field with a smaller aperture size.

 

 

Mikro przesłona połyskomierza gm30s

 

Fig. 1 Micro aperture of the GM30s gloss meter

 

Spód połyskomierza i pole pomiaru gm38

 

 
Fig. 2 Measurement field of the GM38 multi-angle gloss meter

 

 

What units are used to measure gloss?

  

The first unit used for gloss readings is percentage (%). This is the coefficient of light reflection from a surface, expressed as a percentage. In industrial applications, however, gloss measurement relates this result to the amount of light reflected from polished black glass 100 GU in relation to the theoretical absence of reflection 0.00 GU. This gives us GU (Gloss Units) values.

 

 

Which angle should you choose: 20°, 60°, or 85°?

As I mentioned earlier, the basic types of gloss meters are single-angle and multi-angle devices. The device measures gloss at any given angle and in any range. However, for extreme gloss levels, it is worth using measuring angles dedicated to a given range. This does not mean that low or high gloss levels cannot be measured with a single-angle gloss meter, it only means that the results may be less accurate and it is recommended to use an angle of 85° for low ranges and 20° for high ranges. Therefore, if we do not know what gloss we will be dealing with, I suggest choosing a multi-angle gloss meter, i.e., GM38. If you have such a gloss meter, first read the values for the 60° angle and check if the measurement result is within the range of 10–70 GU. If it is below or above this range, use the reading for the angle according to the table below.

  

Gloss level

Initial reading for 60°

Recommended geometry

medium

10 to 70

60°

high

> 70

20°

matte

< 10

85°

 

Gloss meter price

  

The purchase price of a gloss meter depends, of course, on the model selected and the number of angles. However, please remember that subsequent servicing, calibration, and calibration service are equally important. It is worth choosing a manufacturer who not only sells devices but also provides stable and reliable gloss standards to which the device is adjusted.

 

Gloss standard

 

Many studies have already been published on the correct operation of gloss meters. I do not want to bore you here with considerations on measurement consistency, or rather the lack thereof. However, it is worth mentioning a problem that users often encounter. After the initial delight at the ease of measurement, doubts may arise as to whether our gloss meter is working properly, especially when we compare it with another device from a different manufacturer. It may even happen, and this is not a rare case, that the same gloss standard is calibrated in two accredited laboratories with a difference of more than 5 GU. The problem stems from the lack of an original gloss standard that could serve as a starting point for subsequent reproductions. 

 

Each gloss meter comes with a gloss standard to which the device is calibrated (Fig. 1). However, the question arises as to the linearity of measurements in each specified range. It may happen that the gloss meter has been calibrated to a standard of 90 GU, but how will its linear algorithm behave for the 10 GU range? In our opinion, the only possible solution is to correct the calibration standard value yourself and assess whether the values are sufficiently correlated for your environment. Another solution is, of course, to always use devices from the same manufacturer and of the same type. All 3Color gloss meters are prepared and calibrated to gloss standards with a calibration certificate issued by an independent calibration laboratory operating in accordance with ISO 17025.

 

Calibration data correction

 

Regardless of the above information, since 2024, 3Color has introduced the option of independent calibration value correction. This allows users to determine the calibration plate reading value themselves. This solution has been met with great enthusiasm among users. Imagine that you have two customers who have two different types of devices and, in addition, their readings differ from each other. Using a flexible calibration system, we can use different settings for production for customer A and different settings for customer B, without getting into a discussion about which value is correct. Fig. 3 shows the settings for the gloss value correction function for the calibration standard.

 

korekta danych kalibracyjnych w połyskomierzu gm30

 

Fig. 3 Calibration data correction

 

Author: Jarosław Urbański 3Color® Europe

 

Date of publication: 07/05/2024

 

 

 

 

 

 

 

 

 

 

glossmeter